OLTC Transition Resistor Assembly Specification

  • Product Type
  • OLTC (On Load Tap Changer) Transition Resistor Assembly
  • Material
  • Stainless Steel, Copper, High-Grade Insulation Material
  • Capacity
  • Up to 245 kV transformers
  • Output Power
  • Up to 1500 kVA
  • Protection
  • Insulation Cover, Temperature Resistant Housing
  • Output Voltage
  • Up to 220 kV
  • Output Current
  • Up to 3500 A
  • Output Type
  • AC
  • Current Waveform
  • Sine Wave
  • Application
  • Distribution and Power Transformers OLTC operation
  • Size
  • Customized as per requirement
  • Weight
  • 8-30 kg (depending on type)
  • Dimension (L*W*H)
  • As per transformer design
  • Color
  • Metallic Grey
  • Conformity Standards
  • IEC 60214, IS 1866
  • Dielectric Strength
  • Above 2500 V AC
  • Creepage Distance
  • As per IEC/IS standards
  • Temperature Rise
  • <50C above ambient
  • Packaging Type
  • Sealed Wooden/Metal Box
  • Short Circuit Withstand
  • Compliant with transformer duty
  • Mounting Type
  • Panel Mounted with Customized Terminal Connectors
  • Mechanical Endurance
  • 40,000 Operations Minimum
  • Resistance Tolerance
  • 5%
  • Contact Material
  • Silver-Plated or Copper Alloy
 

OLTC Transition Resistor Assembly Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 500 Pieces Per Week
  • Delivery Time
  • 2-10 Days
  • Main Domestic Market
  • All India
 

About OLTC Transition Resistor Assembly



Discover the superlative OLTC Transition Resistor Assembly-popular among leading transformer manufacturers and power utilities for its famed reliability and robust performance. Featuring a dielectric strength above 2500 V AC, resistance tolerance within 5%, and a temperature rise <50C above ambient, this assembly ensures towering endurance with at least 40,000 mechanical operations. Panel mounting is seamless with customized terminal connectors, and you get silver-plated or copper alloy contacts for exceptional conductivity. Conformity to IEC 60214 and IS 1866 standards adds trusted quality. Order today to equip transformers up to 245 kV!

Versatile Applications of OLTC Transition Resistor Assembly

The OLTC Transition Resistor Assembly is indispensable for distribution and power transformer OLTC operations. Application media include high-voltage AC environments, while installation methods involve panel mounting with tailored terminal connectors. This assembly's adaptability suits both indoor and outdoor substations. Apart from transformer tap changers, it can be employed in unique industrial setups requiring controlled current transitions, making it the preferred choice for reliable power control across various sectors.


Swift Delivery and Hassle-Free Logistics

Our OLTC Transition Resistor Assemblies are shipped with utmost care using reliable transportation and transport services across the domestic market. The products are packed securely in sealed wooden or metal boxes, ensuring safe transit. Typical delivery time depends on order size and customization requirements, with quick dispatch from major FOB ports in India. Sample policies are tailored upon request to support smooth procurement, allowing you to experience our quality before placing large-scale orders.


FAQ's of OLTC Transition Resistor Assembly:


Q: How does the OLTC Transition Resistor Assembly enhance transformer performance?

A: The assembly manages current transitions smoothly during OLTC operations, reducing arcing and extending the lifespan of transformer components by ensuring superlative dielectric strength and reliable resistance control.

Q: What are the mounting and connection options provided for this resistor assembly?

A: It is designed for convenient panel mounting and comes with customized terminal connectors to meet specific installation requirements, accommodating both silver-plated and copper alloy contact materials.

Q: Where is the OLTC Transition Resistor Assembly typically used?

A: This assembly is mainly used in distribution and power transformers for OLTC operations, but it also finds application in specialized industrial setups demanding robust current transition control.

Q: What is the typical delivery time and how are products transported?

A: Delivery times vary based on customization and order volume, but we use trusted domestic market transport services to ensure prompt and safe transportation to your desired location.

Q: What standards and safety features does the assembly adhere to?

A: The product conforms to IEC 60214 and IS 1866 standards, featuring insulation covers, temperature-resistant housing, and a creepage distance as per IEC/IS specifications for enhanced protection.

Q: What is the process for requesting samples or large orders?

A: You can request samples under our flexible sample policy, and place orders for bulk quantities through a simple procurement process supported by our sales and transport teams.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in OLTC Spare Parts Category

Ctr Make Oltc Spare Parts

Ctr Make Oltc Spare Parts

Price 4500 INR / Piece

Minimum Order Quantity : 1 Piece

Size : Standard/Customized

Product Type : OLTC Spare Parts

Material : Copper, Brass, Insulating Material

Application : On Load Tap Changer Transformers

OLTC Directional Sequence Switch

OLTC Directional Sequence Switch

Price 3000 INR / Piece

Minimum Order Quantity : 1 Piece

Size : Standard

Product Type : Selector Switch

Material : MS

Application : Industrial

OLTC Bearing Plate Energy Accumulator Assly

OLTC Bearing Plate Energy Accumulator Assly

Price 5000 INR / Piece

Minimum Order Quantity : 10 Pieces

Size : Standard, Customizable

Product Type : OLTC Bearing Plate Energy Accumulator Assly

Material : Cast Iron

Application : Power Transformer, TRANSFORMER



Back to top